RTD Pt100/Pt1000 Sensors

RTD Pt100/Pt1000 Sensors

VIPL Instruments Temperature Products line includes platinum and nickel RTDs & temperature sensor ICs. Platinum and Nickel sensors are both resistance temperature detectors with a variety of temperature ranges from -200°C to +1000°C, Nickel has higher resolution within a smaller temperature range. We also offer custom RTDs in both platinum and nickel with user specified values for TCR, nominal resistance, etc. We also have semiconductor temperature sensors that feature highly accurate measurement within a limited temperature range. They are ideal for mobile applications due to their low power consumption. A Resistance Temperature Detector operates on the principle of the change in electrical resistance in wire as a function of temperature.

VIPL Instruments Mineral Insulated RTD sensors are made with compacted magnesium oxide (MgO) that make our sensors durable and vibration resistant. This range of products is widely used in industries like chemicals, food and pharmaceuticals. The measuring element in Mineral Insulated RTD can be designed in several configurations and conforms to the IEC 751 standard for RTD sensors. The sensors are made with weatherproof aluminum heads that protect the inner construction. As per the application, these mineral insulated RTD sensors can be constructed of Pt50, Pt100, Pt200, Pt500 or Pt1000; with 2, 3 or 4 wires single or dual assembly; and in Class A or B. Radix Mineral Insulated RTDs with Terminal Head offer high-utility by virtue of the mineral insulated sheaths which can be very long and bent or coiled as per the application. Choose from standard assemblies, free rotating fittings, hex nipples, round nipple connections, NUN assemblies, adjustable compression fittings, fixed flange connections or adjustable flange connections

RTD Assembly with Screwed/Flanged Connection

Special Features:

Spring loaded design for positive contact with thermowell

Available in various connections & sheath diameters, Non-bendable sheath

Termination: Aluminum head with threaded cap and chain, Different type of terminal heads

Elements terminated into nickel plated brass terminals mounted on high purity ceramic terminal block

Single/Dual cable entries & cable gland

Application:

Such assemblies are generally inserted in existing Thermowells/protection tubes

This assembly can be provided with threaded connection and Thermowell

Push Fit type Bearing RTD

Special Features:

Available in various sheath diameters, Lead wires of your choice Reference Standard: IEC -751/DIN 43760

Application:

Bearing Temperature measurement used by equipment/instrument manufacturer.

 

RTD Insert with Terminal Block/SS Base

Special Features:

Mineral insulation enables flexibility and durability. Spring loaded design for positive contact with thermowell Available in various standard sheath diameters and sheath materials, Transmitter output 4-20Ma (Optional), Reference Standard: IEC – 751/DIN 43760

Application:

Used as a spare or replacement RTD element in existing RTD assembly.

Autoclave Sensors

 Special Features:

Designed for the pharmaceutical industry.

Eliminates the problem associated with ordinary probes where the pressure cycling the autoclave can force moisture inside the probe.

 

Push Fit type Bearing RTD

Special Features:

Available in various sheath diameters, Lead wires of your choice Reference Standard: IEC -751/DIN 43760

Application:

Bearing Temperature measurement used by equipment/instrument manufacturer.

 

RTD Insert with Terminal Block/SS Base

Special Features:

Mineral insulation enables flexibility and durability. Spring loaded design for positive contact with thermowell Available in various standard sheath diameters and sheath materials, Transmitter output 4-20Ma (Optional), Reference Standard: IEC – 751/DIN 43760

Application:

Used as a spare or replacement RTD element in existing RTD assembly.

Autoclave Sensors

 Special Features:

Designed for the pharmaceutical industry.

Eliminates the problem associated with ordinary probes where the pressure cycling the autoclave can force moisture inside the probe.

Acid & Alkalies RTD

Special Features:

Plastic terminal head, stainless head optional. Titanium Sheath for longer life. Available up to 1000mm. length up to 200°C. Teflon coated SS316 Sheath protects against acids & alkalies

Clamp-on RTD

 Special Features:

For Pipe/ Cylindrical surface temperature measurement where welding, drilling, etc. are not possible. Range -20 to 200°C.

RTD for Automobiles

 Special Features:

PTFE insulated cable as standard. “O” rings prevent leakage of fluid. -20 to 200°C range. Flexible steel spring ensures easy insertion.

Sanitary RTD

Special Features:

Used in food, beverages, pharmaceutical and chemical process where contamination & cleanliness are of concern. Tri-clover made of SS316L. Range -20 to 250°C, other ranges are also available.

Acid & Alkalies RTD

Special Features:

Plastic terminal head, stainless head optional. Titanium Sheath for longer life. Available up to 1000mm. length up to 200°C. Teflon coated SS316 Sheath protects against acids & alkalies

Clamp-on RTD

 Special Features:

For Pipe/ Cylindrical surface temperature measurement where welding, drilling, etc. are not possible. Range -20 to 200°C.

RTD for Automobiles

 Special Features:

PTFE insulated cable as standard. “O” rings prevent leakage of fluid. -20 to 200°C range. Flexible steel spring ensures easy insertion.

Sanitary RTD

Special Features:

Used in food, beverages, pharmaceutical and chemical process where contamination & cleanliness are of concern. Tri-clover made of SS316L. Range -20 to 250°C, other ranges are also available.

Transition Joint RTD
Special Features:
Easy to use model, PTFE insulted and jacketed cables, stainless steel overall braided cables available. Standard models for -20 to 250°C range, other ranges available. SS316 Sheath, SS316L optional. Integral cable makes the assembly light and easy to install. Supplied with 1meter cable or in multiples thereof. Without Process connection type RTD. With adjustable compression fitting RTD. Angular construction is also available.